My Sourcing

LanguageEnglish

Please enter a valid keyword with 2 or more characters / numbers.

Mediomics
Enquire

Disclaimer

Some links on this website may take you to other third-party sites and you acknowledge and agree that HKTDC and the HKTDC Affiliates have no responsibility for the accuracy or availability of any information provided by those linked websites.

Links to other websites do not constitute an endorsement by HKTDC of such websites or the Information, products, advertising, or other materials available on those websites.

Share this page
Bridge-It® L-Methionine (L-Met) Fluorescence Assay Kit
Share this page
Model No.:
1-1-1005B
Size:
96 well format
Type:
Assay Kit
Description
Contact Supplier
Description
Fast and Easy detection of L-methionine levels and enzymes involved in using Methionine as the substrate or as the product!

The Mediomics Bridge-It® L-methionine fluorescence assay method is based on a combination of well-established fluorescence measurement techniques and a new assay platform design that utilizes DNA-binding proteins as biosensors for their respective small molecule coregulators (ligands). The affinity of the DNA sequence-specific MetJ methionine repressor protein for its unique DNA binding site is greatly increased in the presence of its ligand, S-adenosyl methionine (SAM). For this assay, the MetJ consensus sequence was split into two approximately equal DNA “half-sites” with one half fragment labeled with fluorescein and the other half fragment labeled with Oyster® 645 fluorophore3,4. The relative amount of SAM present in a test sample will influence the amount of DNA-MetJ protein complex formation in the assay. When this complex forms, it brings the fluorescence labeled-DNA half-sites into close proximity and causes a measurable change (increase) in fluorescence signal emission that can be readily measured using a microplate reader (wavelength settings: absorption 485 nm; emission 665 nm). The L-methionine is readily converted to SAM by S-adenosylmethionine synthetase in the presence of ATP and Mg2+. L-Methionine concentrations in test samples are determined using an L- methionine standard curve.

The Bridge-It® L-methionine fluorescence assay method exhibits highly desirable performance characteristics including a high signal to background (S/B) ratio, a good linear dynamic range, and, a detection sensitivity of ~5 μM. The total assay time is 45 minutes.

Bridge-It® L-Methionine (L-Met) Fluorescence Assay Kit is:
Easy
Mix test sample or standard with the Assay solution and incubate
Fast
Read fluorescent signal after 45 minutes of incubation
Sensitive
Assay measures L-Methionine at a lower limit of sensitivity of 5 µM
Flexible
Assay is adaptable to both low- and high-throughput screening formats

More information at :
http://mediomics.com/product/bridge-l-methionine-l-met-fluorescence-assay-kit-96-well-format/

*384 well format also available

Mediomics

Mediomics

Missouri, USA

Manufacturer, Others

You may also like

Unfollow the following supplier?