80KVA UPS Power Backup, 3/1 Phase, Low Frequency UPS
分享此页面
WeChat
Facebook
WhatsApp
複製
产品型号:
HM8K-HM100K
品牌名称:
Prostar
港口:
Foshan, China
付款方式:
TT/LC
最低订购数量:
1
防护:
不平衡负载
电源类型:
交流
输入电压:
380V
输出频率:
50/60Hz
输入频率:
50/60Hz
是否有包装:
有
是否可定制:
是
类型:
在线不间断电源
输出电压:
220V
相数:
单相
适用范围:
安防/监视/警报器
描述
联络供应商
描述
Neptune series UPS is adopting the technology, which combined with the world's most advanced DSP digital control technology currently, and IGBT high frequency Pulse Width Modulation technique (PWM). Double-conversion online topology desi gn makes the output frequency of UPS, which used for tracking, phase-locking, voltage regulator and filter out noise, interference from the power grid fluctuations in pure sine wave power supply, and make the UPS more comprehensive and perfectly protection for the users. After Prostar R&D center elaborative designed for more than 10 yeas, Prostar has designed a modular structure, whose overall operation is 5 times more reliable and stable performance than regular UPS, MTBF is over 300,000 hours.
Neptune Series UPS equipped with standard built-output isolation transformers, static bypass switch and manual maintain switch, making this series UPS has a very high capacity to engage in short-circuit. It could be used for the worst environment. Also it has perfect protect function. Moreover, it has the AC input, over-voltage, under-voltage, output over-voltage, short circuit protection, inverter, rectifier over-temperature protection, voltage under-voltage warning, battery over charging protection and other protections in one, to ensure system operation stably and reliably.
Neptune series UPS includes 3-phase ins and single phase out from HM8K-HM100K, which can be in parallel with 8 units UPS directly, conveniently and fast. flexible parallel technology could be applied to different loads and systems. According to the needs of customers' constitute, it could make N + 1 or N + X construction, but also according to the different needs of customers with different capacity, it could be in parallel with random 8 units UPS, and all the load will be loaded by all 8 units UPS averagely of the parallel redundant UPS system. Any UPS of the parallel redundant system was failed, the UPS will share its load immediately, to ensure system running normally. During the process of the parallel UPS, it does not set the host and the standby one, but was selected by customers flexibly. The first turned on UPS is automatically set to the host, when the host system failed, the host identity immediately transferred to another UPS, thereby ensuring the supply of electricity for clients during the using process, so it could become a true uninterruptible power supply.