Shenzhen Keyingtong Electronic Technology Co., Ltd
请输入包含最少两个字元或数字的关键字。
Switching Power Supply | |||||||
Product features: | |||||||
• Protection function: short circuit, over current and overload; | |||||||
• Reasonable circuit design layout, high conversion efficiency, low temperature rise; | |||||||
• 100% full load aging test; | |||||||
• Small output ripple, high working efficiency, small size and light weight; | |||||||
• Every product has an impact test; | |||||||
specification | |||||||
Type | 12V 200W | 24V 200W | |||||
Output | DC voltage | 12V | 24V | ||||
Rated current | 16.7A | 8.3A | |||||
Current range | 0~16.7A | 0~8.3A | |||||
rated power | 200W | 200W | |||||
Ripple and noise | 120mV | 240mV | |||||
Voltage adjustment | 11.2~12.8 | 23.2~24.8 | |||||
Range | ±2% | ±2% | |||||
Voltage accuracy | ±0.5% | ±0.5% | |||||
Linear adjustment rate | ±1% | ±1% | |||||
Start time | ≤1000ms/230VAC(full loaded) | ||||||
Retention time(Typ.) | 30ms/230VAC(full loaded) | ||||||
Input | Voltage range(V) | 180-240VAC | |||||
Frequency range(Hz) | 47~63Hz | ||||||
Efficiency(Typ.) | 83% | 85% | |||||
AC current(Typ.) | 0.58A 230VAC | ||||||
Inrush current(Typ.) | cold start time <50A/230VAC | ||||||
Leakage current | <0.75mA/240VAC | ||||||
Protection features | Short circuit protection | Protection method: hiccup mode,automatic recovery after abnormal removal. | |||||
Overload protection | 110%~150% of rated output power Protection mode:hiccup mode,automatic recovery after abnormal removal. | ||||||
Condition | Working temperature(℃) | -10℃ - +45℃ | |||||
Working temperature(℃) | 20% - 90%RH,No condensation | ||||||
Storage temperature、humidity | -20℃ - +85℃ ,10% - 95%RH,No condensation | ||||||
Temperature coefficient | ±0.3‰( 0 - 50℃ ) | ||||||
Vibration resistance | 10-500Hz,2g 10min/cycle,X、Y、Z axes each 60 minutes. | ||||||
Safety standard | Withstand voltage(VAC) | I/P-O/P:1.5KVAC,I/P-FG:0.5KVAC,OP-FG:0.5KVAC 60S | |||||
Safety standard | Reference EN/UL60950-1,GB4943 Standard design | ||||||
Insulation resistance | I/P-O/P,I/P-FG,O/P-FG: 100M Ohm/500VDC/25℃ | ||||||
Note | 1. All unspecified parameters are measured at 230VAC voltage input, rated load and 25 degree. | ||||||
2.Ripple and noise voltage:It is measured when a 12-inch twisted pair is used in a 20MHz bandwidth, and 0.1μand 47μ capacitors are connected in parallel at the terminal. | |||||||
3.Accuracy:Including setting error, Linear adjustment rate and load adjustment rate. | |||||||
4.Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test. | |||||||
5.Load adjustment rate measurement method:From 0% to 100% rated load. | |||||||
6.The startup time is measured under the cold start state,and the rapid and frequent switching on and off may increase the startup time. | |||||||
7.When the operating altitude is higher than 2000 meters(6500ft),the operating ring temperature needs to be lowered by 5 degree/1000 meters. | |||||||
Package | product size | 205*55*30(mm)(L*W*H) | | ||||
Carton Quantity | 100PCS | ||||||
Carton Size | 51.5*35.8*22cm | ||||||