RFCI61000-6 Conducted Immunity Test System includes a built-in signal source, a power amplifier and power meter module, a variety of coupling decoupled network (CDN), electromagnetic clamp and current injection clamp developed by external attenuator by LISUN. It is widely used in medical, power, industrial control, new energy charging piles, communication piles and ect for industries. 

Standard:
IEC61000-4-6/EN61000-4-6 (GB/T17626.6)”Electromagnetic compatibility(EMC)- Part 4-6:Testing and measurement techniques- Immunity to conducted disturbances, induced by radio- frequency fields”
ISO11452-4 “Road vehicles — Component test methods for electrical disturbances from narrowband radiated electromagnetic energy- Part 4:Harness excitation methods”

Host Configuration

Output Voltage

LISUN Model:RFCI61000-6-35W(Output power: 35W)

1 ~ 17Vrms(CDN method)

1 ~ 11Vrms(Electromagnetic clamping method)

LISUN Model:RFCI61000-6-85W(Output power: 85W)

1 ~ 30Vrms(CDN method)

1 ~ 18Vrms(Electromagnetic clamping method)

1 ~ 10Vrms(Current injection clamping method)

Output impendance

50Ω

Voltage resident rate

≤ 1.2

Output Frequence

150kHz ~ 230MHz

Harmonic

< 15dBc

Signal source (built-in)

Frequency

9k ~ 1GHz

Output level

-60 ~ 10dBm

Non -row signal

Continuous wave

Modulation

A amplitude modulation modulation frequency: 1Hz ~ 10kHz modulation depth: 1 ~ 99%

Pulse modulation and modulation frequency: 1Hz ~ 1kHz Lights ratio: 1 to 100%

Power amplifier (built-in)

Output Frequency

150kHz ~ 230MHz

Max. output power

LISUN Model RFCI61000-6-35W:+44dBm/35W

LISUN Model RFCI61000-6-85W:+49dBm/85W

Harmonic

< 15dBc

Power meter (built-in)

Input Frequency

9kHz ~ 3GHz

Input Power

-40dBm ~ +30dBm

Attenuator (built-in)

Frequency Range:

DC~1GHz

Max. output power:

100W

Attenuation value:

6dB

Operation (please refer to GB/T17626.6 or IEC61000-4-6: 2014 Terms of Article 7.4.2 Figure 20 to select injection method: CDN method, electromagnetic clamp and current injection clamp method)):
1. The host RFCI61000-6-35W/RFCI61000-6-85W can test the power cables or communications lines with the CDN Coupling Decoupling Network (Optional) of the following models of LISUN: