请输入包含最少两个字元或数字的关键字。
Model | SMT-R12010-VD-P | SMT-R24010-VD-P | SMT-R48010-VD-P | |
Certificate | UL pending / ROHS / SELV | |||
Output | DC Voltage | 12V | 24V | 48V |
Rated current | 0.83A | 0.42A | 0.21A | |
Rated power | 10W | |||
Voltage Tolerance | ±0.5V | |||
Input | Voltage Range | 120-277VAC | ||
Frequency Range | 47 - 63Hz | |||
Power Factor @ full load | ≥0.98@120VAC ≥0.9@277VAC | |||
THD(Typ.) @ full load | ≤15%@120VAC ≤15%@277VAC | |||
Efficiency @ full load | ≥75%@120VAC ≥75%@277VAC | ≥77%@120VAC ≥78%@277VAC | ≥78%@120VAC ≥78%@277VAC | |
AC Current (Max.) | 0.12A | |||
Inrush Current (Typ.) | 2A, 52us @50%Ipeak 120VAC 5.7A, 31us @50%Ipeak 277VAC | |||
Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed. | ||
Over Load | 105%~120% Hiccup mode, recovers automatically after fault condition is removed. | |||
Over temperature | Ambient temperature over 55℃±5℃ , output reduce to 50%; Ambient temperature over 60℃±5℃, output off; When the temperature is reduced to 45℃±5℃ the output returns to 100%. | |||
Environment | Working TEMP. (Ta) | -40~+50℃ (see below derating curve) | ||
Case Temperature (Tc) | 90℃ | |||
Working Humidity | 20 - 90%RH non-condensing | |||
Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH non-condensing | |||
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | |||
Vibration | 10 ~ 500Hz, 2G 12 minutes/cycle, X Y Z axis 72 minutes each | |||
Safety & EMC | Safety standards | UL8750; CAN/CSA-C22.2 No.250.13 | ||
Withstand voltage | I/P-O/P:1.88KVAC | |||
Isolation resistance | I/P-O/P:100MΩ / 500VDC / 25℃ / 70% RH | |||
EMC Immunity | FCC/ICES do not request this test. | |||
EMC Emission | FCC 47 CFR Part 15, Subpart B | |||
Surge Immunity Test | AC Power Line: Differential Mode 1KV | |||
Others | Net Weight | 0.103KG | ||
Dimension | 54*48.2*24mm(Φ*W*H) | |||
Packing | 380*290*155mm 100pcs/CTN | |||
Notes | All parameters NOT specially mentioned are measured at rated load for 120VAC and 25℃of ambient temperature. Derated output is required at low input voltage to ensure long service life. | |||