Model | SMT-R12025-VD-P | SMT-R24025-VD-P | |
Certificate | UL pending / ROHS / SELV | ||
Output | DC Voltage | 12V | 24V |
Rated current | 2.08A | 1.04A | |
Rated power | 25W | ||
Voltage Tolerance | ±0.5V | ||
Input | Voltage Range | 120-277VAC | |
Frequency Range | 47 - 63Hz | ||
Power Factor @ full load | ≥0.98@120VAC ≥0.91@277VAC | ≥0.97@120VAC ≥0.92@277VAC | |
THD(Typ.) @ full load | ≤10%@120VAC ≤15%@277VAC | ≤15%@120VAC ≤20%@277VAC | |
Efficiency @ full load | ≥75%@120VAC ≥75%@277VAC | ≥80%@120VAC ≥76%@277VAC | |
AC Current (Max.) | 0.29A | ||
Inrush Current (Typ.) | 1.92A, 68us @50%Ipeak 120VAC 6.08A, 44us @50%Ipeak 277VAC | ||
Protection | Short Circuit | Hiccup mode, recovers automatically after fault condition is removed. | |
Over Load | 105%~120% Hiccup mode, recovers automatically after fault condition is removed. | ||
Over temperature | Ambient temperature over 55℃±5℃ , output reduce to 50%; Ambient temperature over 60℃±5℃, output off; When the temperature is reduced to 45℃±5℃ the output returns to 100%. | ||
Environment | Working TEMP. | -40~+50℃ (see below derating curve) | |
Working Humidity | 20 - 90%RH non-condensing | ||
Storage TEM.,Humidity | -40 - +80℃,10 - 95% RH non-condensing | ||
TEMP.coefficient | ±0.03%/℃(0 - 50℃) | ||
Vibration | 10 ~ 500Hz, 2G 12 minutes/cycle, X Y Z axis 72 minutes each | ||
Safety & EMC | Safety standards | UL8750; CAN/CSA-C22.2 No.250.13 | |
Withstand voltage | I/P-O/P:1.88KVAC | ||
Isolation resistance | I/P-O/P:100MΩ / 500VDC / 25℃ / 70% RH | ||
EMC Immunity | FCC/ICES do not request this test. | ||
EMC Emission | FCC 47 CFR Part 15, Subpart B | ||
Surge Immunity Test | AC Power Line: Differential Mode 1KV | ||
Others | Net Weight |
| |
Dimension | 69.4*62.9*24mm(Φ*W*H) | ||
Packing | 385*290*190mm 80pcs/CTN | ||
Notes | All parameters NOT specially mentioned are measured at rated load for 120VAC and 25℃of ambient temperature. Derated output is required at low input voltage to ensure long service life. | ||