我的采购

请输入包含最少两个字元或数字的关键字。

广西星宇智能电气有限公司
查询

免责声明

本网页的连接可将阁下连往其他网址而阁下承认并同意,香港贸发局及其各联号公司对连接网址所提供的任何资讯的准确性或有效性,不负任何责任。

连接其他网址并不构成香港贸发局对该等网址或者该等网址所提供的资讯丶产品丶广告或其他材料的认可。

分享此页面
Small Current Grounding Line Selection Device
分享此页面
产品型号:
YH-B811
描述
联络供应商
描述
  • Small Current Grounding Line Selection Device
  • Nearly 100% of the correct rate of the election line
  • Since 2006, YH-B811, respectively, Xi'an Jiaotong University, Cape Laboratory, Guangxi Academy of Sciences, such as over 10,000 anti-real, dynamic mode, inversion experiment, the correct rate of more than 98% line selection
  • So far, it is the first and only one in a number of laboratories to carry out dynamic test small current grounding line selection device
  • October 2007, YH-B811 in Xi'an Jiaotong University completed 1269 digital dynamic test, the correct line selection 1248 times, the correct line rate really 98.3%
  • August 2008 in the Cape Laboratory (formerly the National Relay Quality Inspection Center) completed 120 dynamic test, the correct rate of 100% line selection.
  • From September to November 2011, YH-B811 completed 340 dynamic model tests at the Electric Power Research Institute of Guangxi Power Grid Corporation. The correct selection line was 334 times, and the correct rate of selection was 98.2%
  • It is the only one in the power grid, oil, coal, metallurgy and other industries in many fields done on-site artificial grounding test of small current grounding line selection device
  • 2009 - 2013, YH-B811, respectively, in the water power supply bureau, Shenzhen Power Supply Bureau, Kaili Power Supply Bureau, Text Electric Academy, Xiangtan Coal Mine, Daqing Oilfield, Xinshanzi Petrochemical, Laiwu Steel Group, Guizhou Power Grid 9 Times the artificial ground test, the correct line selection 40 times, the correct rate of true selection line 95.2%
  • As of April 30, 2013, the country 617 operating the scene, a single phase ground a total of 5739 times, of which the correct line selection 5661 times, the correct rate of 98.64%
  • Revolutionary breakthrough in the technical principles
  • The YH-B811 small current line selection device adopts the theory of line selection based on the characteristics of the transient zero sequence current in the adaptive buffering feature band. The high-speed sampling, extraction and analysis of the harmonic current of the instantaneous zero sequence current
  • The use of the unique nature of the frequency band to identify the fault line. Adapt to all the center point of the indirect grounding system, not the system operation and a variety of fault conditions

广西星宇智能电气有限公司

广西星宇智能电气有限公司

中国内地广西壮族自治区

出口商, 制造商

您或许喜欢

确定要取消关注此供应商?