Please enter a valid keyword with 2 or more characters / numbers.
model | SMT-012-100TDDR | SMT-024-096TDDR2 | ||
Output | DC Voltage | 12VDC | 24VDC | |
Voltage Accuracy | ±5% | ±5% | ||
Rated current | 8.33Amp | 4.0Amp | ||
Rated power | 100W | 96W (Class 2) | ||
Voltage Regulation | ±0.5% | |||
Load Regulation | ±1% ±1% | |||
Input | Voltage Range | 100-277 VAC | ||
Frequency Range | 47~63HZ | |||
Power Factor ( Typ.) | 0.98@120VAC ,0.95@277VAC | 0.98@120VAC ,0.95@277VAC | ||
| THD(Typ. ) @ full load | <20%@120VAC & 277VAC | ||
Full Load Efficiency(Typ.) | 83%@120VAC, 85%@277VAC | 83%@120VAC, 86%@277VAC | ||
AC Current(Typ.) | 1.3A | |||
Inrush Current(Typ.) | 20A, 50%, 1.6ms @120VAC; 25A, 50% 1.2ms @277VAC | |||
Leakage current | <0.5mA | |||
Protection | Short Circuit | shut down o/p voltage, re-power on to recover after fault condition removed | ||
Over Loading | ≤120% Hiccup mode,recovers automatically after fault condition is removed | |||
Over temperature | 100℃±10℃ shut down o/p voltage, automatically recover after cooling. | |||
Environment | Working TEMP. | -40~+60℃ | ||
Working Humidity | 20~90%RH,non-condensing | |||
Storage TEM.,Humidity | -40~+80℃,10~95%RH | |||
TEMP.coefficient | ±0.03%/℃(0~50℃) | |||
Vibration | 10~500Hz,2G 10min./1 cycle,period for 60min. each along X,Y,Z axes | |||
Safety&EMC | Safety standards | UL8750+UL1310 , CAN/CSA-C22.2 No.250.13 | ||
Withstand voltage | I/P-O/P:1.88KVac | |||
Isolation resistance | I/P-O/P:100MΩ/500VDC/25℃/70%RH | |||
EMC EMISSION | FCC 47 CFR Part 15 ,Subpart B | |||
Others | Weight | 0.4Kg | ||
Size | 55*90*100mm(L*W*H) | |||
packing | 50PCS/CTN , carton size:330*330*130mm | |||
Notes | All parameters NOT specially mentioned are measured at 110VAC, 277VAC input , Rated load and 25℃of ambient temperature. Tolerance:includes set us tolerance,line regulation and load regulation . The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. | |||