Please enter a valid keyword with 2 or more characters / numbers.
Some links on this website may take you to other third-party sites and you acknowledge and agree that HKTDC and the HKTDC Affiliates have no responsibility for the accuracy or availability of any information provided by those linked websites.
Links to other websites do not constitute an endorsement by HKTDC of such websites or the Information, products, advertising, or other materials available on those websites.
Portable 7KW EV Charger for Home New energy electric vehicles
Datasheet | EU Standard | US Standard | ||
Model | KSEVC-PE-7KW | KSEVC-PU-7.6KW | KSEVC-PU-9.6KW | |
Rated Power | Rated Power | 7KW | 7.68KW | 9.6KW |
Input | Power Supply | L+N+PE | L+N+PE(L1+L2+PE) | L+N+PE(L1+L2+PE) |
Rated Voltage | 230V AC | 110V/240V AC | 110V/240V AC | |
Frequency | 50/60Hz | 50/60Hz | 50/60Hz | |
Output | Output Voltage | 230V AC | 240V AC | 240V AC |
Maximum Current | 32A | 32A | 40A | |
Maximum Power | 7KW | 7.68KW | 9.6KW | |
Charge Connector | Type 2 socket | Type 1 | Type 1 | |
User Interface | Enclosure | plastic | plastic | plastic |
Front Panel | plastic | plastic | plastic | |
LCD Display | 2.4inch | 2.4inch | 2.4inch | |
RFID Reader | NFC | NFC | NFC | |
Communication | Start Mode | Plug | Plug | Plug |
Emergency Stop | × | × | × | |
Energy Meter | √ | √ | √ | |
Communication (optional) | Wifi | √ | √ | √ |
TUYA | √ | √ | √ | |
Ethernet | × | × | × | |
3G/4G | × | × | × | |
OCPP 1.6 json | × | × | × | |
Safety | RCD | 30mA Type A + 6mA DC | AC20mA | AC20mA |
Ingress Protection | IP55 | IP55 | IP55 | |
Impact Protection | IK08 | IK08 | IK08 | |
Protection | Over current protection, Residual current protection, Short circuit protection, Ground protection, Surge protection, Over/Under voltage protection, Over temperature protection,Cp protection | Over current/Residual current/ Short circuit/Ground /Surge/Over/Under voltage/Over temperature /Cp .protection | Over current/Residual current/ Short circuit/Ground /Surge/Over/Under voltage/Over temperature /Cp .protection | |
Certification | CE | UL | UL | |
Certification Standard | IEC 62196 Type2 | SAE J1772 | SAE J1772 | |
Environment | Warranty | 2 years | 2 years | 2 years |
Installation | Wall-mount/Pole-mount | Wall-mount/Pole-mount | Wall-mount/Pole-mount | |
Work Temperature | -30℃~+50℃ | ﹣30℃~﹢55℃ | ﹣30℃~﹢55℃ | |
Work Humidity | 5%~95% | 5%~95% | 5%~95% | |
Work Altitude | <2000m | <2000m | <2000m | |
Package | Product Dimension | 240*110*80mm (H*W*D) | 240*110*80mm (H*W*D) | 240*110*80mm (H*W*D) |
Package Dimension | 400*300*140mm (H*W*D) | 400*300*140mm (H*W*D) | 400*300*140mm (H*W*D) | |
Net Weight | 3.5kg | 3.5kg | 3.5kg | |
Gross Weight | 4kg | 4kg | 4kg | |
External Package | Carton | Carton | Carton |