Model: YCL100 constant voltage series
Power: 100W max.
Input: 100-240VAC 50/60Hz
Output Voltage: 12-48V
Output Current: 100MA-8300MA
Inrush Current: 65 Amps max. at 230VAC/50Hz,full load
Leakage Current: 2.5mA Max. at 264VAC input
No Load Power Consumption : <0.5W
Protections: Short Circuit /Over Current /Over Voltage/over temperature protection
Short Circuit Protection (SCP): Protection to Zero Voltage
Over Voltage Protection (OVP): ≤Vout*150%
Over Current Protection (OCP): 110%-180%
Working TEMP.: -20°C-50°C
Working Humidity: 5%-90% RH non-condensing
Storage TEMP.,Humidity and altitude: -40℃ ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL.
Certificates and approvals: TUV-GS CB
EMI EMISSION: Conducted disturbance at mains terminals:EN 55015 Radiation Test&Conduction Test: EN 55015 Magnetic Emission:EN55015:2013
Harmonic Test : EN 61000-3-2
Voltage fluctuation and Flicker Test : EN 61000-3-3
EMS IMMUNITY: ESD Test:IEC 61000-4-2
RS Test:IEC 61000-4-3
EFT/B Immunity Test:IEC61000-4-4
Surge Immunity :IEC61000-4-5
Conduted RF Immunity: IEC 61000-4-6
Power frequency magnetic field:IEC 61000-4-11 Voltage dips and interruptions,100% reduction: IEC 61000-4-11 Voltage dips and interruptions,30% reduction: IEC 61000-4-11
MTBF: 100000 hours minimum at full load at 25℃ ambient
Life: 3-5 years alternative