請輸入包含最少兩個字母或數字的關鍵字。
Blood Pressure Monitor
Noninvasive Blood Pressure Measurement System
MODEL: HiPRESSURE2024V14
The Blood Pressure Monitor is a digital monitor intended for use in measuring blood pressure and pulse rate with a wrist circumference ranging from 13.5cm to 21.5cm (about 5⅓˝-8½˝). It is intended for adult indoor use only.
The Blood Pressure Monitor is designed to measure systolic pressure, diastolic pressure and pulse rate of adult population by a non-invasive technique, with an inflatable cuff wrapped around the wrist. The method to define systolic and diastolic pressure is similar to auscultatory method, though it uses an electronic pressure sensor rather than a stethoscope and mercury manometer. The sensor converts tiny alternations of cuff pressure into electrical signals. Based on analysis of these signals, the systolic and diastolic blood pressure is defined, and the pulse rate is calculated. This is an extensively used technique applied in blood pressure monitors, also known as “oscillometric method”. The main components of the Blood Pressure Monitor include main unit and wrist cuff. For the outer housing of the main unit, it’s made of ABS material. The cuff is suitable for adults with wrist circumference of 13.5cm to 21.5cm. The cuff is consisted of fabric and an inflatable bladder inside. For critical electronic components, there is PCB, thermistor, pressure pump, motor, release valve and pressure sensor. The device also enjoys a function of detecting irregular pulse rate. When measurements were performed, the monitor will record all pulse intervals and calculate the average. If two or more pulse intervals were recorded, and the difference between each interval and the average is larger than ±25% of the average; or if four or more pulse intervals were recorded, and the difference between each interval and the average is larger than ±15% of the average, the irregular pulse symbol will be displayed along with measurement results. An embedded Bluetooth wireless connection module in the device allows it to connect with matching receiving ends. When a measurement is done, the results will be displayed on LCD, and the measured data will be transferred to the APP via Bluetooth.
Type of Use OTC
Battery (2*AAA, 3V DC)
Automatic deflation with air pump
DISPLAY: LCD
MEMORY: 199*2
CLINICAL: Compliance with ISO 81060-2
Clinical data: The device was tested according to ISO 81060-2:2018+A1:2020 Non-invasive sphygmomanometers – Part 2: Clinical validation of automated measurement type. The clinical study aimed to validate the accuracy of the blood pressure monitor with cuff. 258 datasets were collected from 86 subjects. There are 86 adult subjects with aged 55.7±11.5,58.1% male and 41.9% female. The mean differences between reference BPs and device readings were -0.27±3.18/-0.80±2.51mmHg for systolic BP (SBP)/diastolic BP (DBP) of criterion 1, and - 0.27±2.60/-0.80±2.06mmHg for SBP/DBP of criterion 2.