Filter housing key features
›All components comply with FDA CFR Title 21 & EC/1935/2004
›Suitable for contact with food
›Connected using a flange, threaded fitting and weld ends
›12 different sizes
Sterile filter key features
›Complies with cGMP requirements
›Can be used at temperatures up to 180 °C (356 °F)
›Support cylinders and end caps made of stainless steel 1.4301
›Separation rate ≥ 99.99998% with regard to ≤ 0.2 µm
›Suitable for sterilisation using same and counter-directional flow and VPHP
Steam filter key features
›Can be used at temperatures up to 180 °C (356 °F)
›Degree of porosity > 50%
›Double EPDM O-ring
›Burst pressure 10 bar (at 20°C)
›Safely separates out impurities, such as rust, particles and dust
›Also suitable for culinary steam (1 µm)
Sterile filter element
Max. volume flow
8 bar [a] (m 3 /h)**:60~2880
Filter medium: Borosilicate, support cylinder and end caps: Stainless steel 1.4301
** At 20°C and 1 bar(a)
Steam filter element
Deposition rate
1 µm /5 µm /25 µm
Filter medium: sintered stainless steel filter tube 1.4404; End caps: Stainless steel 1.4301