Power measure of active power (KW), reactive power (KVAR), apparent power (KVA), power factor (PF).
PF (cos O) for 3O4W, 3O3W, 1O2W, 1O3W.
Triple display: KW + V + A easy to read.
AC current up to 1000A, AC voltage up to 600V.
INRUSH (100mS), HOLD and PEAK functions.
Max and min recorded functions.
Auto power off (10 min), black-light.
Dimensions of conductor: O35mm.
EN61010-1 Approval.
Over-voltage category III 1000.
Specifications:
AC 1000A true RMS clamp on model: DPM-041.
CE mark safety approval.
AC current (true RMS).
Range: 0.0 to 600.0A, 600A to 1000A.
Resolution: 0.1A/1A.
Accuracy: ± (1.5% rdg + 10dgts) on 50Hz to 60Hz.
± (3.5% rdg + 10dgts) on 45Hz to 400Hz.
AC voltage (true RMS).
Range: 0.0 to 600.0V.
Resolution: 0.1V.
Accuracy: ± (1% rdg + 5dgts) on 20Hz to 100Hz.
± (6% rdg + 5dgts) on 100Hz to 400Hz.
Input impedance: 1MΩ.
Power measurement accuracy.
To make sure measuring accuracy, clamp the jaw several times to align the contact surface in place to get the optimal measuring results before you take measurement.
Single phase or three phase load with sine wave input at 50/60Hz.