請輸入包含最少兩個字母或數字的關鍵字。
Introduction:
The pulse vacuum autoclave extracts vacuum and fills steam into the sterilization room for many times to make
the sterilization chamber reach a certain vacuum degree, and then fills saturated steam to reach the set pressure
and temperature, so as to achieve the purpose of sterilization of the sterilized substance.
Application:
Widely used in damp heat sterilized of medical equipment, sanitary materials, etc.
Introduction:
The pulse vacuum autoclave extracts vacuum and fills steam into the sterilization room for many times to make
the sterilization chamber reach a certain vacuum degree, and then fills saturated steam to reach the set pressure
and temperature, so as to achieve the purpose of sterilization of the sterilized substance.
Application:
Widely used in damp heat sterilized of medical equipment, sanitary materials, etc.
Features:
Brand-new operation interface: The LCD touch screen can display real-time information such as temperature,
pressure, times, operation status, fault alarm, and equipment operating curve, making the terilization information
more intuitive and clear, and it is convenient for users to observe the operating status of the equipment.
Multiple safety protection devices: automatic over-temperature protection device, multiple control and protection
of evaporator, door safety interlock protection, double over-pressure protection device, etc.
Door structure: BKM-K18/23B autoclave adopts a manual door structure, BKM-Z18/23B autoclave adopts
automatic door structure. It is could quick and convenient to operate, and effectively protects the human body
and prevents burns.
Vacuum system: It adopts high-efficiency vacuum system, low working noise, ultimate vacuum can reach more
than-80Kpa, fast pumping speed, good dryness of items, and more thorough sterilization.
Diversified procedures: Ther are fast procedures, encapsulation procedures, rubber procedures, dressing procedures,
liquid procedures, liquid customization, soild customization, media stenilization, media dissolution and other procedures,
as well as B&D testing and vacuum testing procedures.
High-effciency air filter: 0.22µm sterilizing high-efficiency air filter, the filtration efficiency is not less than 99.5%,
to ensure that the vacuum-breaking air is sterile air, and to avoid re-contamination of sterile materials.
Recording device: The equipment is equipped with a thermal printer and USB interface as stanard, which can
record the data of the entire sterilization process in real time.
Other function: automatic opereation of the whole process of preheating, replacement, heating, sterilization,
exhaust steam, and vacuum drying.