請輸入包含最少兩個字母或數字的關鍵字。
Project | Performance parameters | YITENSEN 11+ | |
Source | DC millivolt | Range | -10 ~ 1100mV |
Accuracy= ±(% of the set value+% of range) | 0.02%+0.01% | ||
Resolution | 1uV | ||
DC voltage | Range | -1 ~ 11V | |
Accuracy= ±(% of the set value+% of range) | 0.02%+0.01% | ||
Resolution | 0.1mV | ||
DC current | Range | 0 ~ 22mA | |
Accuracy= ±(% of the set value+% of range) | 0.02%+0.02% | ||
Resolution | 1uA | ||
Sink current | Range | 0 ~ 22mA | |
Accuracy ±(% of the set value+% of range) | 0.02%+0.02% | ||
Resolution | 1uA | ||
External power supply | 5 ~ 28V | ||
Resistance | Range | 0 ~ 40KΩ | |
Accuracy= ±(% of the set value+% of range) | 0.02%+0.02% | ||
Resolution | 0.01Ω/0.1Ω/1Ω | ||
Frequency | Range | 1Hz ~100KHz | |
Accuracy | ±2words | ||
Resolution | 0.01Hz/1Hz/0.1KHz/2KHz | ||
Pulse | Frequency | 1Hz ~10KHz | |
Range | 1 ~100000cyc | ||
Accuracy | ±2words | ||
Resolution | 1cyc | ||
Switch | Range | 1Hz ~100KHz | |
Accuracy | ±2words | ||
Resolution | 0.01Hz/1Hz/0.1KHz/2KHz | ||
Thermocouple | Range | 10types(R/S/K/E/J/T/B/N/L/U) | |
Accuracy | 0.4℃ | ||
Resolution | 0.1℃/1℃ | ||
RTD | Range | 6types(Pt100/Pt200/Pt500/ Pt1000/Cu10/Cu50) | |
Accuracy | 0.2℃ | ||
Resolution | 0.1℃ | ||
Measure | DC millivolt | Range | N/A |
Accuracy= ±( % of Reading+ % of Range) | |||
Resolution | |||
DC voltage | Range | N/A | |
Accuracy= ±( % of Reading+ % of Range) | |||
Resolution | |||
DC current | Range | N/A | |
Accuracy= ±( % of Reading+ % of Range) | |||
Resolution | |||
Resistance | Range | N/A | |
Accuracy= ±( % of Reading+ % of Range) | |||
Resolution | |||
Frequency | Range | N/A | |
Accuracy | |||
Resolution | |||
Switch | Range | N/A | |
Threshold | |||
Pressure | Range | N/A | |
Accuracy= ±( % of Reading+ % of Range) | |||
Resolution | |||
Loop power supply | Range | N/A | |
Accuracy | |||
The maximum current | |||
Thermocouple | Range | N/A | |
Accuracy | |||
Resolution | |||
RTD | Range | N/A | |
Accuracy | |||
Resolution | |||
Continuity beeper | Range | N/A | |
Accuracy | |||
Resolution | |||
Other functions | Backlight | √ | |
Auto Power-off | √ | ||
Charging function | √ | ||
Room temperature display | √ | ||
Battery detection | √ | ||
Communication function | RS232 serial communication, can realize remote control instrument by the device driver software | ||
The mathematical treatment | Data hold,zero,average | ||
Characteristic | |||
Safety | EN61010-1:2001 | ||
Insulation | DC500V /50MΩ | ||
EMC | EN61326-1:2006 | ||
Authentication | CE | ||
Display | Double display on the LCD screen | ||
Power supply | 4×1.5V AAA alkaline battery | ||
Size | 205 × 95 × 42 mm | ||
Weight | Approx. 1100 G | ||
Standard Quantity Per Carton | 10pcs | ||
Standard Carton Measurement | 395mm*385mm*260mm | ||
Standard Carton Cross Weight | 10.4Kg |
Product Features:
1, The basic accuracy of the output is 0.02%, with 6 digits output display.
2, The output function: DC voltage, DC current, ohm, analog transmitter, thermocouple, thermal
resistance, frequency, pulse, switch.
3, The DC current can provide 25% and 100% of the manual step, automatic step and automatic
ramp output.
4, The thermocouple output can provide high-precision automatic cold junction compensation,
can be display as ℃ or ℉ temperature.
5, Can be equipped with high-precision temperature probe, accuracy: ±0.2 ℃.
6, Large-screen LCD multi-data display, can also display: DC current and value, thermocouple,
thermal resistance of the temperature and its corresponding value, etc.
7, The operating performance of the keyboard configuration, the output set the increase and
decrease keys and LCD display set value corresponding to the bit.