RANGE
Accuracy
model

97
DC voltage
40mV/400mV
±(1.0%+6)
4V/40V/400V
±(0.5%+4)
1000V
±(0.5%+5)
AC voltage
40mV/400mV
±(1.0%+6)
4V/40V/400V
±(0.8%+10)
750V
±(1.2%+10)
DC current
400uA/4000uA
±(1.0%+10)
40mA/400mA
±(1.2%+8)
4A/10A
±(1.2%+10)
AC current
400uA/4000uA/40mA/400mA
±(1.5%+10)
4A/10A
±(2.0%+5)
resistance
400Ω
±(0.8%+5)
4kΩ/40kΩ/400kΩ/4MΩ
±(0.8%+4)
40MΩ
±(1.2%+10)
capacitance
6nF
±(5.0%+40)
60nF/600nF/6uF/60uF/600uF
±(3.5%+20)
60mF/100mF
±10%
6mF
±(5.0%+10)
frequency
10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/20MHz
±(0.5%+10)
The instrument is a stable and high performance digital multimeter driven by battery. It uses the LCD with 42mm high to make the readings clearly. The instrument has the function of measuring DCV, ACV, DCA, ACA, Resistance and Capacitance, Frequency, Diode, Triode, Continuity test, Temperature, Auto power off (can be canceled) and backlight function. The instrument takes dual-integral A/D converter as key point, is an excellent tools. It’s an ideal tool for lab, factory and family. The new generation series of productions add NCV (non-contact ACV induction measurement) and torch function on the basis of the original function. 
 This series meter meets the standard of IEC61010 (the safety standards request issued by IEC or equal GB4793.1 standards). Read
it before operation.1. Input over range is prohibited in each range during the test.2. Voltage less than 36V is safety voltage.
When measuring voltage higher than 36V DC, 25V AC, check the connection, insulation of test leads to avoid electric shock.3. When
changing function and range, test leads should be removed from testing point.4. Select correct function and range.5. Don’t operate
the meter when the battery case and back cover are not fixed6. Don’t input voltage during the resistance measurement.7. Test lead
should be removed from testing point before changing the batteries or fuses, and turn off the power.8. Comply with local and
national safety regulations, wear personal protective equipment (approved rubber gloves, masks and flame retardant clothing,
etc.), to prevent electric shock and arc injury caused by exposure of dangerous electric conductor.9. Make measurements using only