我的採購

    請輸入包含最少兩個字母或數字的關鍵字。

    Shenzhen Victor Hi-Tech Co Ltd
    查詢
    分享此頁面
    Victor 97 Auto Range True RMS AC/DC Voltage Multimeter
    分享此頁面
    美元 $11.88 - 美元 $15.20
    美元 $12.50 - 美元 $16.00
    生產所需時間:
    40 日
    運送方式:
    EXW
    型號編號:
    vc97
    品牌:
    Victor
    Operating Mode: :
    Auto Range
    Backlight: :
    Yes
    True RMS: :
    Yes
    Low battery indication: :
    Yes
    Data Hold: :
    Yes
    Application:
    multimeter
    描述
    聯絡供應商
    描述
    Specification

    RANGE
    Accuracy
    model

    97
    DC voltage
    40mV/400mV
    ±(1.0%+6)
    4V/40V/400V
    ±(0.5%+4)
    1000V
    ±(0.5%+5)
    AC voltage
    40mV/400mV
    ±(1.0%+6)
    4V/40V/400V
    ±(0.8%+10)
    750V
    ±(1.2%+10)
    DC current
    400uA/4000uA
    ±(1.0%+10)
    40mA/400mA
    ±(1.2%+8)
    4A/10A
    ±(1.2%+10)
    AC current
    400uA/4000uA/40mA/400mA
    ±(1.5%+10)
    4A/10A
    ±(2.0%+5)
    resistance
    400Ω
    ±(0.8%+5)
    4kΩ/40kΩ/400kΩ/4MΩ
    ±(0.8%+4)
    40MΩ
    ±(1.2%+10)
    capacitance
    6nF
    ±(5.0%+40)
    60nF/600nF/6uF/60uF/600uF
    ±(3.5%+20)
    60mF/100mF
    ±10%
    6mF
    ±(5.0%+10)
    frequency
    10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/20MHz
    ±(0.5%+10)
    The instrument is a stable and high performance digital multimeter driven by battery. It uses the LCD with 42mm high to make the readings clearly. The instrument has the function of measuring DCV, ACV, DCA, ACA, Resistance and Capacitance, Frequency, Diode, Triode, Continuity test, Temperature, Auto power off (can be canceled) and backlight function. The instrument takes dual-integral A/D converter as key point, is an excellent tools. It’s an ideal tool for lab, factory and family. The new generation series of productions add NCV (non-contact ACV induction measurement) and torch function on the basis of the original function. 
     This series meter meets the standard of IEC61010 (the safety standards request issued by IEC or equal GB4793.1 standards). Read
    it before operation.1. Input over range is prohibited in each range during the test.2. Voltage less than 36V is safety voltage.
    When measuring voltage higher than 36V DC, 25V AC, check the connection, insulation of test leads to avoid electric shock.3. When
    changing function and range, test leads should be removed from testing point.4. Select correct function and range.5. Don’t operate
    the meter when the battery case and back cover are not fixed6. Don’t input voltage during the resistance measurement.7. Test lead
    should be removed from testing point before changing the batteries or fuses, and turn off the power.8. Comply with local and
    national safety regulations, wear personal protective equipment (approved rubber gloves, masks and flame retardant clothing,
    etc.), to prevent electric shock and arc injury caused by exposure of dangerous electric conductor.9. Make measurements using only
    the correct measurement standard class (CAT), voltage and current rated probe, test conductor and adapter.10. Safety symbols“”
    exists high voltage,“”GND,“” dual insulation“” must refer to manual,“ ”low battery